fabsurplus.com




Teradyne J750 VLSI Tester for Sale


SDI fabsurplus.com is pleased to announce the availability of the following listed used Teradyne J750 VLSI Tester.
Please click on the "Send More Details" button at the end of the J750 description, if you'd like to get more details, photos and specifications of this VLSI Tester, and your request for this equipment will be forwarded to our SDI sales representatives automatically.
This Teradyne J750 VLSI Tester is available for immediate sale.
Crating, refurbishment and delivery for this equipment can be quoted on request.


Teradyne J750 Equipment Details

SDI ID: 97760
Manufacturer: Teradyne
Model: J750
Description: VLSI Tester
Version: TEST
Vintage: 01.06.2001
Quantity: 1
Sales Condition: as is where is
Lead Time: immediately
Sales Price: 120,000 USD
Comments:

Currently operational.

Configuration:-

    512 pin, APMUX1, Channel boardx7, DPSX4
    Windows XP, PC model Z800
    Includes manipulator
    Channel board 16M, part no 239-026-31
    power condition AC415v,out AC 208v to tester



%JOB_START - Beginning CUB Calibration test on

slot 18 at 6:02:42 PM on 12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Starting Channel Drive Levels: Vih Vil

- Starting Channel Compare Levels: Voh Vol

%JOB_END - ****PASSED**** CUB Calibration of

slot 18 (5008F05) at 6:02:43 PM

%JOB_START - Beginning Channel_Board_DIB

Calibration test on slot 0 at

6:02:50 PM on 12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Systemwide functionality and continuity to

slot 0

- Starting dib_test

- Temperature at PE Ch00 is 53 deg C

- Temperature at PE Ch60 is 37 deg C

- Temperature at Incoming Air is 23 deg C

- Temperature at TG Ch00 is 42 deg C

- Starting BPMU Force Voltage

- Starting Bpmu Clamp Voltage

- Starting Bpmu Measure Voltage

- Starting Bpmu Measure Current

- Starting Bpmu Force current

- Starting Bpmu Limit current

- Starting Channel Drive Levels: Vih Vil

- Starting Channel Compare Levels: Voh Vol

- Starting Channel Clamps: Vch Vcl

- Starting Channel Loads: Ioh Iol

- Starting Channel Load Threshold: Vt

- Starting HV Channel Drive Levels

- Starting HV Channel Drive Current

- Ppmu Mi Warmup 6:05:09 PM

- Ppmu Mi Warmup 6:05:09 PM

- Starting Ppmu Force Voltage

- Starting Ppmu Measure Voltage

- Starting Ppmu Force Current Ppmu Force 200ua

- Starting Ppmu Force Current Ppmu Force 2ma

- Starting Ppmu Measure 2ma

- Continuing Ppmu Measure Current chan 15

- Continuing Ppmu Measure Current chan 31

- Continuing Ppmu Measure Current chan 47

- Continuing Ppmu Measure Current chan 63

- Starting Ppmu Measure 200ua

- Continuing Ppmu Measure Current chan 15

- Continuing Ppmu Measure Current chan 31

- Continuing Ppmu Measure Current chan 47

- Continuing Ppmu Measure Current chan 63

- Starting Ppmu Measure Int 20ua

- Continuing Ppmu Measure Current chan 15

- Continuing Ppmu Measure Current chan 31

- Continuing Ppmu Measure Current chan 47

- Continuing Ppmu Measure Current chan 63

- Starting Ppmu Measure Int 2ua

- Continuing Ppmu Measure Current chan 15

- Continuing Ppmu Measure Current chan 31

- Continuing Ppmu Measure Current chan 47

- Continuing Ppmu Measure Current chan 63

- Starting Ppmu Measure Int 200na

- Continuing Ppmu Measure Current chan 15

- Continuing Ppmu Measure Current chan 31

- Continuing Ppmu Measure Current chan 47

- Continuing Ppmu Measure Current chan 63

- Finished Channel Calibration

%JOB_END - ****PASSED**** Channel_Board_DIB

Calibration of slot 0 (C000A77) at

6:08:17 PM

%JOB_START - Beginning Channel_Board_DIB

Calibration test on slot 1 at

6:08:24 PM on 12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Systemwide functionality and continuity to

slot 1

- Starting dib_test

- Temperature at PE Ch00 is 54 deg C

- Temperature at PE Ch60 is 35 deg C

- Temperature at Incoming Air is 22 deg C

- Temperature at TG Ch00 is 39 deg C

- Starting BPMU Force Voltage

- Starting Bpmu Clamp Voltage

- Starting Bpmu Measure Voltage

- Starting Bpmu Measure Current

- Starting Bpmu Force current

- Starting Bpmu Limit current

- Starting Channel Drive Levels: Vih Vil

- Starting Channel Compare Levels: Voh Vol

- Starting Channel Clamps: Vch Vcl

- Starting Channel Loads: Ioh Iol

- Starting Channel Load Threshold: Vt

- Starting HV Channel Drive Levels

- Starting HV Channel Drive Current

- Ppmu Mi Warmup 6:10:45 PM

- Ppmu Mi Warmup 6:10:45 PM

- Starting Ppmu Force Voltage

- Starting Ppmu Measure Voltage

- Starting Ppmu Force Current Ppmu Force 200ua

- Starting Ppmu Force Current Ppmu Force 2ma

- Starting Ppmu Measure 2ma

- Continuing Ppmu Measure Current chan 79

- Continuing Ppmu Measure Current chan 95

- Continuing Ppmu Measure Current chan 111

- Continuing Ppmu Measure Current chan 127

- Starting Ppmu Measure 200ua

- Continuing Ppmu Measure Current chan 79

- Continuing Ppmu Measure Current chan 95

- Continuing Ppmu Measure Current chan 111

- Continuing Ppmu Measure Current chan 127

- Starting Ppmu Measure Int 20ua

- Continuing Ppmu Measure Current chan 79

- Continuing Ppmu Measure Current chan 95

- Continuing Ppmu Measure Current chan 111

- Continuing Ppmu Measure Current chan 127

- Starting Ppmu Measure Int 2ua

- Continuing Ppmu Measure Current chan 79

- Continuing Ppmu Measure Current chan 95

- Continuing Ppmu Measure Current chan 111

- Continuing Ppmu Measure Current chan 127

- Starting Ppmu Measure Int 200na

- Continuing Ppmu Measure Current chan 79

- Continuing Ppmu Measure Current chan 95

- Continuing Ppmu Measure Current chan 111

- Continuing Ppmu Measure Current chan 127

- Finished Channel Calibration

%JOB_END - ****PASSED**** Channel_Board_DIB

Calibration of slot 1 (5007DCE) at

6:13:52 PM

%JOB_START - Beginning Channel_Board_DIB

Calibration test on slot 2 at

6:14:00 PM on 12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Systemwide functionality and continuity to

slot 2

- Starting dib_test

- Temperature at PE Ch00 is 57 deg C

- Temperature at PE Ch60 is 40 deg C

- Temperature at Incoming Air is 23 deg C

- Temperature at TG Ch00 is 45 deg C

- Starting BPMU Force Voltage

- Starting Bpmu Clamp Voltage

- Starting Bpmu Measure Voltage

- Starting Bpmu Measure Current

- Starting Bpmu Force current

- Starting Bpmu Limit current

- Starting Channel Drive Levels: Vih Vil

- Starting Channel Compare Levels: Voh Vol

- Starting Channel Clamps: Vch Vcl

- Starting Channel Loads: Ioh Iol

- Starting Channel Load Threshold: Vt

- Starting HV Channel Drive Levels

- Starting HV Channel Drive Current

- Ppmu Mi Warmup 6:16:21 PM

- Ppmu Mi Warmup 6:16:21 PM

- Starting Ppmu Force Voltage

- Starting Ppmu Measure Voltage

- Starting Ppmu Force Current Ppmu Force 200ua

- Starting Ppmu Force Current Ppmu Force 2ma

- Starting Ppmu Measure 2ma

- Continuing Ppmu Measure Current chan 143

- Continuing Ppmu Measure Current chan 159

- Continuing Ppmu Measure Current chan 175

- Continuing Ppmu Measure Current chan 191

- Starting Ppmu Measure 200ua

- Continuing Ppmu Measure Current chan 143

- Continuing Ppmu Measure Current chan 159

- Continuing Ppmu Measure Current chan 175

- Continuing Ppmu Measure Current chan 191

- Starting Ppmu Measure Int 20ua

- Continuing Ppmu Measure Current chan 143

- Continuing Ppmu Measure Current chan 159

- Continuing Ppmu Measure Current chan 175

- Continuing Ppmu Measure Current chan 191

- Starting Ppmu Measure Int 2ua

- Continuing Ppmu Measure Current chan 143

- Continuing Ppmu Measure Current chan 159

- Continuing Ppmu Measure Current chan 175

- Continuing Ppmu Measure Current chan 191

- Starting Ppmu Measure Int 200na

- Continuing Ppmu Measure Current chan 143

- Continuing Ppmu Measure Current chan 159

- Continuing Ppmu Measure Current chan 175

- Continuing Ppmu Measure Current chan 191

- Finished Channel Calibration

%JOB_END - ****PASSED**** Channel_Board_DIB

Calibration of slot 2 (5000CBF) at

6:19:29 PM

%JOB_START - Beginning Channel_Board_DIB

Calibration test on slot 3 at

6:19:36 PM on 12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Systemwide functionality and continuity to

slot 3

- Starting dib_test

- Temperature at PE Ch00 is 55 deg C

- Temperature at PE Ch60 is 41 deg C

- Temperature at Incoming Air is 23 deg C

- Temperature at TG Ch00 is 45 deg C

- Starting BPMU Force Voltage

- Starting Bpmu Clamp Voltage

- Starting Bpmu Measure Voltage

- Starting Bpmu Measure Current

- Starting Bpmu Force current

- Starting Bpmu Limit current

- Starting Channel Drive Levels: Vih Vil

- Starting Channel Compare Levels: Voh Vol

- Starting Channel Clamps: Vch Vcl

- Starting Channel Loads: Ioh Iol

- Starting Channel Load Threshold: Vt

- Starting HV Channel Drive Levels

- Starting HV Channel Drive Current

- Ppmu Mi Warmup 6:21:57 PM

- Ppmu Mi Warmup 6:21:57 PM

- Starting Ppmu Force Voltage

- Starting Ppmu Measure Voltage

- Starting Ppmu Force Current Ppmu Force 200ua

- Starting Ppmu Force Current Ppmu Force 2ma

- Starting Ppmu Measure 2ma

- Continuing Ppmu Measure Current chan 207

- Continuing Ppmu Measure Current chan 223

- Continuing Ppmu Measure Current chan 239

- Continuing Ppmu Measure Current chan 255

- Starting Ppmu Measure 200ua

- Continuing Ppmu Measure Current chan 207

- Continuing Ppmu Measure Current chan 223

- Continuing Ppmu Measure Current chan 239

- Continuing Ppmu Measure Current chan 255

- Starting Ppmu Measure Int 20ua

- Continuing Ppmu Measure Current chan 207

- Continuing Ppmu Measure Current chan 223

- Continuing Ppmu Measure Current chan 239

- Continuing Ppmu Measure Current chan 255

- Starting Ppmu Measure Int 2ua

- Continuing Ppmu Measure Current chan 207

- Continuing Ppmu Measure Current chan 223

- Continuing Ppmu Measure Current chan 239

- Continuing Ppmu Measure Current chan 255

- Starting Ppmu Measure Int 200na

- Continuing Ppmu Measure Current chan 207

- Continuing Ppmu Measure Current chan 223

- Continuing Ppmu Measure Current chan 239

- Continuing Ppmu Measure Current chan 255

- Finished Channel Calibration

%JOB_END - ****PASSED**** Channel_Board_DIB

Calibration of slot 3 (500944A) at

6:25:04 PM

%JOB_START - Beginning Channel_Board_DIB

Calibration test on slot 4 at

6:25:12 PM on 12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Systemwide functionality and continuity to

slot 4

- Starting dib_test

- Temperature at PE Ch00 is 59 deg C

- Temperature at PE Ch60 is 40 deg C

- Temperature at Incoming Air is 21 deg C

- Temperature at TG Ch00 is 40 deg C

- Starting BPMU Force Voltage

- Starting Bpmu Clamp Voltage

- Starting Bpmu Measure Voltage

- Starting Bpmu Measure Current

- Starting Bpmu Force current

- Starting Bpmu Limit current

- Starting Channel Drive Levels: Vih Vil

- Starting Channel Compare Levels: Voh Vol

- Starting Channel Clamps: Vch Vcl

- Starting Channel Loads: Ioh Iol

- Starting Channel Load Threshold: Vt

- Starting HV Channel Drive Levels

- Starting HV Channel Drive Current

- Ppmu Mi Warmup 6:27:34 PM

- Ppmu Mi Warmup 6:27:34 PM

- Starting Ppmu Force Voltage

- Starting Ppmu Measure Voltage

- Starting Ppmu Force Current Ppmu Force 200ua

- Starting Ppmu Force Current Ppmu Force 2ma

- Starting Ppmu Measure 2ma

- Continuing Ppmu Measure Current chan 271

- Continuing Ppmu Measure Current chan 287

- Continuing Ppmu Measure Current chan 303

- Continuing Ppmu Measure Current chan 319

- Starting Ppmu Measure 200ua

- Continuing Ppmu Measure Current chan 271

- Continuing Ppmu Measure Current chan 287

- Continuing Ppmu Measure Current chan 303

- Continuing Ppmu Measure Current chan 319

- Starting Ppmu Measure Int 20ua

- Continuing Ppmu Measure Current chan 271

- Continuing Ppmu Measure Current chan 287

- Continuing Ppmu Measure Current chan 303

- Continuing Ppmu Measure Current chan 319

- Starting Ppmu Measure Int 2ua

- Continuing Ppmu Measure Current chan 271

- Continuing Ppmu Measure Current chan 287

- Continuing Ppmu Measure Current chan 303

- Continuing Ppmu Measure Current chan 319

- Starting Ppmu Measure Int 200na

- Continuing Ppmu Measure Current chan 271

- Continuing Ppmu Measure Current chan 287

- Continuing Ppmu Measure Current chan 303

- Continuing Ppmu Measure Current chan 319

- Finished Channel Calibration

%JOB_END - ****PASSED**** Channel_Board_DIB

Calibration of slot 4 (8012468) at

6:30:41 PM

%JOB_START - Beginning Channel_Board_DIB

Calibration test on slot 6 at

6:30:49 PM on 12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Systemwide functionality and continuity to

slot 6









- Starting dib_test

- Temperature at PE Ch00 is 54 deg C

- Temperature at PE Ch60 is 42 deg C

- Temperature at Incoming Air is 24 deg C

- Temperature at TG Ch00 is 41 deg C

- Starting BPMU Force Voltage

- Starting Bpmu Clamp Voltage

- Starting Bpmu Measure Voltage

- Starting Bpmu Measure Current

- Starting Bpmu Force current

- Starting Bpmu Limit current

- Starting Channel Drive Levels: Vih Vil

- Starting Channel Compare Levels: Voh Vol

- Starting Channel Clamps: Vch Vcl

- Starting Channel Loads: Ioh Iol

- Starting Channel Load Threshold: Vt

- Starting HV Channel Drive Levels

- Starting HV Channel Drive Current

- Ppmu Mi Warmup 6:32:59 PM

- Ppmu Mi Warmup 6:32:59 PM

- Starting Ppmu Force Voltage

- Starting Ppmu Measure Voltage

- Starting Ppmu Force Current Ppmu Force 200ua

- Starting Ppmu Force Current Ppmu Force 2ma

- Starting Ppmu Measure 2ma

- Continuing Ppmu Measure Current chan 399

- Continuing Ppmu Measure Current chan 415

- Continuing Ppmu Measure Current chan 431

- Continuing Ppmu Measure Current chan 447

- Starting Ppmu Measure 200ua

- Continuing Ppmu Measure Current chan 399

- Continuing Ppmu Measure Current chan 415

- Continuing Ppmu Measure Current chan 431

- Continuing Ppmu Measure Current chan 447

- Starting Ppmu Measure Int 20ua

- Continuing Ppmu Measure Current chan 399

- Continuing Ppmu Measure Current chan 415

- Continuing Ppmu Measure Current chan 431

- Continuing Ppmu Measure Current chan 447

- Starting Ppmu Measure Int 2ua

- Continuing Ppmu Measure Current chan 399

- Continuing Ppmu Measure Current chan 415

- Continuing Ppmu Measure Current chan 431

- Continuing Ppmu Measure Current chan 447

- Starting Ppmu Measure Int 200na

- Continuing Ppmu Measure Current chan 399

- Continuing Ppmu Measure Current chan 415

- Continuing Ppmu Measure Current chan 431

- Continuing Ppmu Measure Current chan 447

- Finished Channel Calibration

%JOB_END - ****PASSED**** Channel_Board_DIB

Calibration of slot 6 (5000FA8) at

6:36:07 PM

%JOB_START - Beginning Channel_Board_DIB

Calibration test on slot 7 at

6:36:14 PM on 12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Systemwide functionality and continuity to

slot 7

- Starting dib_test

- Temperature at PE Ch00 is 51 deg C

- Temperature at PE Ch60 is 44 deg C

- Temperature at Incoming Air is 24 deg C

- Temperature at TG Ch00 is 41 deg C

- Starting BPMU Force Voltage

- Starting Bpmu Clamp Voltage

- Starting Bpmu Measure Voltage

- Starting Bpmu Measure Current

- Starting Bpmu Force current

- Starting Bpmu Limit current

- Starting Channel Drive Levels: Vih Vil

- Starting Channel Compare Levels: Voh Vol

- Starting Channel Clamps: Vch Vcl

- Starting Channel Loads: Ioh Iol

- Starting Channel Load Threshold: Vt

- Starting HV Channel Drive Levels

- Starting HV Channel Drive Current




- Ppmu Mi Warmup 6:38:33 PM

- Ppmu Mi Warmup 6:38:33 PM

- Starting Ppmu Force Voltage

- Starting Ppmu Measure Voltage

- Starting Ppmu Force Current Ppmu Force 200ua

- Starting Ppmu Force Current Ppmu Force 2ma

- Starting Ppmu Measure 2ma

- Continuing Ppmu Measure Current chan 463

- Continuing Ppmu Measure Current chan 479

- Continuing Ppmu Measure Current chan 495

- Continuing Ppmu Measure Current chan 511

- Starting Ppmu Measure 200ua

- Continuing Ppmu Measure Current chan 463

- Continuing Ppmu Measure Current chan 479

- Continuing Ppmu Measure Current chan 495

- Continuing Ppmu Measure Current chan 511

- Starting Ppmu Measure Int 20ua

- Continuing Ppmu Measure Current chan 463

- Continuing Ppmu Measure Current chan 479

- Continuing Ppmu Measure Current chan 495

- Continuing Ppmu Measure Current chan 511

- Starting Ppmu Measure Int 2ua

- Continuing Ppmu Measure Current chan 463

- Continuing Ppmu Measure Current chan 479

- Continuing Ppmu Measure Current chan 495

- Continuing Ppmu Measure Current chan 511

- Starting Ppmu Measure Int 200na

- Continuing Ppmu Measure Current chan 463

- Continuing Ppmu Measure Current chan 479

- Continuing Ppmu Measure Current chan 495

- Continuing Ppmu Measure Current chan 511

- Finished Channel Calibration

%JOB_END - ****PASSED**** Channel_Board_DIB

Calibration of slot 7 (5000FDA) at

6:41:40 PM

%JOB_START - Beginning DPS_DIB Calibration test

on slot 21 at 6:41:48 PM on

12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Starting DPS Calibration on slot 21


- Calibrating DPS Voltage on slot 21

- Calibrating DPS Current Limit on slot 21

- Calibrating DPS Current Measure (50uA

Range) on slot 21

- Calibrating DPS Current Measure (500uA

Range) on slot 21

- Calibrating DPS Current Measure (10mA

Range) on slot 21

- Calibrating DPS Current Measure (100mA

Range) on slot 21

- Calibrating DPS Current Measure (1A

Range) on slot 21

- Finished DPS Calibration on slot 21


%JOB_END - ****PASSED**** DPS_DIB Calibration

of slot 21 (1FBEFD) at 6:42:03 PM

%JOB_START - Beginning DPS_DIB Calibration test

on slot 22 at 6:42:10 PM on

12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Starting DPS Calibration on slot 22


- Calibrating DPS Voltage on slot 22

- Calibrating DPS Current Limit on slot 22

- Calibrating DPS Current Measure (50uA

Range) on slot 22

- Calibrating DPS Current Measure (500uA

Range) on slot 22

- Calibrating DPS Current Measure (10mA

Range) on slot 22

- Calibrating DPS Current Measure (100mA

Range) on slot 22

- Calibrating DPS Current Measure (1A

Range) on slot 22

- Finished DPS Calibration on slot 22


%JOB_END - ****PASSED**** DPS_DIB Calibration

of slot 22 (802DA66) at 6:42:25 PM

%JOB_START - Beginning DPS_DIB Calibration test

on slot 23 at 6:42:32 PM on

12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Starting DPS Calibration on slot 23


- Calibrating DPS Voltage on slot 23

- Calibrating DPS Current Limit on slot 23

- Calibrating DPS Current Measure (50uA

Range) on slot 23

- Calibrating DPS Current Measure (500uA

Range) on slot 23

- Calibrating DPS Current Measure (10mA

Range) on slot 23

- Calibrating DPS Current Measure (100mA

Range) on slot 23

- Calibrating DPS Current Measure (1A

Range) on slot 23

- Finished DPS Calibration on slot 23


%JOB_END - ****PASSED**** DPS_DIB Calibration

of slot 23 (5008C73) at 6:42:47 PM

%JOB_START - Beginning DPS_DIB Calibration test

on slot 24 at 6:42:55 PM on

12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Starting DPS Calibration on slot 24


- Calibrating DPS Voltage on slot 24

- Calibrating DPS Current Limit on slot 24

- Calibrating DPS Current Measure (50uA

Range) on slot 24

- Calibrating DPS Current Measure (500uA

Range) on slot 24

- Calibrating DPS Current Measure (10mA

Range) on slot 24

- Calibrating DPS Current Measure (100mA

Range) on slot 24

- Calibrating DPS Current Measure (1A

Range) on slot 24

- Finished DPS Calibration on slot 24


%JOB_END - ****PASSED**** DPS_DIB Calibration

of slot 24 (50069E5) at 6:43:09 PM

%JOB_START - Beginning APMU Calibration test on

slot 5 at 6:43:17 PM on 12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Starting APMU Calibration on slot 5


- Finished APMU Calibration on slot 5


%JOB_END - ****PASSED**** APMU Calibration of

slot 5 (4000AA5) at 6:45:20 PM

%JOB_START - Beginning AC Calibration at

6:45:27 PM on 12/31/2019

Workbook Rev V7.23.10 IG-XL

Version: 3.40.09 DIB # 3008C31

Rev 701A

- Beginning Digital Channel Timing Calibration

- Building List of Digital Channels

- Checking CalDIB AC Continuity for all

Digital Channels

- Calibrating Super Linear Interpolator (SLI)

- Measuring Cub Round Trip Delay

- Measuring RF Matrix Delay

- Calibrating Drive Edges

- Calibrating Receive Edges

- Calibrating Receive Window

- Calibrating Mux Drive

- Calibrating Receive Mux

- Completed Digital Channel Timing Calibration

%JOB_END - ****PASSED**** AC Calibration at

6:53:21 PM

- Writing to System Calibration file - Begin (up

to 5 minutes)

- Writing to System Calibration file - End

Categories:
Send Me More Details about this item.



Not the item you were looking for?

Ask SDI fabsurplus.com!

If you are looking for a specific piece of semiconductor equipment let us know what type of semiconductor manufacturing equipment you would like to buy, and we will conduct a search for what you are looking for.

Inquiry

The data provided herein is not an offer capable of acceptance.
The information contained on this page is, to our knowledge and information, accurate, but it may contain errors and therefore we do not warrant the completeness or accuracy of the information contained on this page.
Any offer by you to purchase the equipment described on this page shall be subject to our standard terms and conditions of sale.

sdi logo

Established in 1998, SDI has now built up an international network of sales agents and offices.

SDI has evolved into one of the largest semiconductor equipment brokerages by concentrating on professionalism, customer service and value for money.

Read more about us




Due to heavy demand from our many customers,
SDI-Fabsurplus has decided to better serve an elite selection of our regular customers by offering a Subscription Fee service,
providing a premium level of service in which our customers can opt-in to gain immediate access
and regular weekly updates to the most valuable information about semiconductor equipment available in the worldwide market,
together with prioritised support directly from our sales team via phone, website and e-mail.



View all TEST ATE for sale

Search for Teradyne items for sale

Search for J750 items for sale


Ask SDI fabsurplus.com! If you can't find what you need, or are looking for a specific piece of semiconductor equipment. Let us know what type of semiconductor manufacturing equipment you would like to buy, and we will conduct a search for what you are looking for.

Inquiry



sdi logo

Click here for all contact information.
SDI-Fabsurplus Srl Italy, and SDI-FABSURPLUS LLC. N. America




SDI fabsurplus.com works by using the latest technology to continuously monitor the used equipment market place.
If you want to join our mailing list, please send click on the button below to send an e-mail to subscribe to our monthly equipment news update.

Request monthly equipment news





We'd love to get your feedback about our website and our services!
Fill in the Feedback Form